Flomero Pericardial Bioprosthesis
Flomero Pericardial Bioprosthesis

Flomero Pericardial Bioprosthesis

MOQ : 10 Pieces

Flomero Pericardial Bioprosthesis Specification

  • Finish Type
  • Smooth, Biocompatible Finish
  • Function
  • Mimics Native Heart Valve Function
  • Instruments Type
  • Implantable Medical Device
  • Surface Finish
  • Treated for Biocompatibility
  • Disposable Or Reusable
  • Disposable - Single Use
  • Diameter
  • Size dependent, typically 19-33mm
  • Instrument
  • Pericardial Bioprosthesis
  • Type
  • Artificial Heart Valve
  • Material
  • Pericardial Tissue (Bovine or Equine) with Metal/Stent Framework
  • Condition
  • New
  • Technology
  • Bioprosthetic Valve Technology
  • Portable
  • No
  • Rechargeable
  • No
  • Foldable
  • No
  • Sterilized
  • Yes
  • Use Type
  • Cardiac Surgery
  • Usage
  • Replacement of Failed Native Heart Valve
  • Operating Type
  • Manual (Surgically Implanted)
  • Dimension (L*W*H)
  • Size dependent (Available in multiple sizes)
  • Weight
  • Lightweight (few grams)
  • Application
  • Heart Valve Replacement
  • Features
  • High Hemodynamic Performance, Durable, Biocompatible
  • Type Of Equipment
  • Cardiac Prosthesis
  • Size
  • Typically ranges from 19mm to 33mm (outer diameter)
  • Suture Ring
  • Low-profile, sewing cuff
  • Indications
  • Mitral and Aortic Valve Replacement
  • Radiopacity
  • Stent markers for radiographic identification
  • Sterilization Method
  • Gamma radiation or ETO sterilized
  • Durability
  • Designed for Long-term Implantation
  • Valve Stent
  • Flexible or semi-rigid stent
  • Leaflet Material
  • Glutaraldehyde-treated pericardial tissue
  • Shelf Life
  • Up to 3-5 years pre-implantation (unopened, sterile packaging)
  • Valve Design
  • Tri-leaflet Design
 

Flomero Pericardial Bioprosthesis Trade Information

  • Minimum Order Quantity
  • 10 Pieces
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 2-5 Days
  • Main Domestic Market
  • All India
 

About Flomero Pericardial Bioprosthesis



Flomero Pericardial Bioprosthesis offers a rare and top-notch solution for mitral and aortic valve replacement. Crafted from glutaraldehyde-treated bovine or equine pericardial tissue, its ace tri-leaflet design and semi-rigid or flexible stent ensure phenomenal hemodynamic performance. The valve features a low-profile suture ring for easy implantation and treated, smooth, biocompatible surfaces for durability. Gamma radiation or ETO sterilized, each valve arrives in special-rate, sterile packaging, with radiopaque stent markers for precise placement. Personalise your inventory-Flomero delivers reliability for surgeons and swift healing for patients.

Flomero Pericardial Bioprosthesis: Features & Competitive Edge

The Flomero Pericardial Bioprosthesis stands out for its phenomonal durability, biocompatibility, and ace hemodynamic performance. Its tri-leaflet design with a low-profile, sewing cuff ensures top surgical outcomes, while stent markers enable accurate radiographic identification. Lightweight yet robust, this artificial valve mimics the efficiency of native heart valves. It is tailored for both mitral and aortic applications, giving medical institutions a significant competitive advantage in cardiac surgery and patient recovery.


Flomero Pericardial Bioprosthesis: Supply & Market Details

We maintain an extraordinary supply ability for the Flomero Pericardial Bioprosthesis, ensuring timely quotations for bulk orders. Primary domestic markets in India experience prompt goods transport, with each order packaged securely before being handed over to logistic partners. Sample units are available for clinical review, providing healthcare providers an opportunity to assess quality first-hand before purchasing. Flomero prioritises commercial accessibility and seamless delivery for all customers.


FAQ's of Flomero Pericardial Bioprosthesis:


Q: How is the Flomero Pericardial Bioprosthesis sterilized before use?

A: Each Flomero Pericardial Bioprosthesis undergoes sterilization using either gamma radiation or ETO, ensuring it reaches hospitals in a sterile, ready-to-use state.

Q: What tissues and materials are used in the construction of the valve?

A: The valve is fabricated from glutaraldehyde-treated bovine or equine pericardial tissue, integrated with a metal or semi-rigid/flexible stent and radiopaque markers for easy identification during surgery.

Q: When should the Flomero Pericardial Bioprosthesis be used?

A: This device is indicated for use in cases requiring replacement of failed native mitral or aortic heart valves, offering a dependable solution for long-term cardiac function.

Q: Where can the Flomero Pericardial Bioprosthesis be commercially sourced in India?

A: The Flomero Pericardial Bioprosthesis is available through trusted exporters, suppliers, and traders specialized in cardiac surgical equipment throughout India's main domestic markets.

Q: What is the process for requesting a quotation or sample unit?

A: To obtain a quotation or sample, healthcare providers may directly contact our sales team. We provide samples for clinical evaluation and prepare commercial orders with prompt delivery and secure transport logistics.

Q: How does the design benefit surgical implantation and patient outcomes?

A: The valve's tri-leaflet structure and low-profile sewing cuff simplify surgical handling and promote a snug fit, while durable, biocompatible materials afford patients a remarkable post-operative prognosis.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cardiovascular Instrument Category

Sewing Ring

Sewing Ring

Minimum Order Quantity : 10 Pieces

Material : Other, Medical Grade Fabric and Synthetic Polymer

Type : Other, Annuloplasty Ring

Size : Multiple sizes available

Features : Flexible, Durable, Biocompatible

Application : Other, Heart Valve Annuloplasty Procedures

Miral Annuloplasty Ring

Miral Annuloplasty Ring

Minimum Order Quantity : 10 Pieces

Material : Other, Biocompatible medical grade material (commonly titanium core with polyester fabric covering)

Type : Other, Rigid/ Semirigid Ring

Size : Available in multiple sizes (typically 24 mm to 38 mm)

Features : Anatomically shaped, radiopaque markers, suture needles attached

Application : Other, Ring for mitral valve support

Miral Annuloplasty Ring

Miral Annuloplasty Ring

Minimum Order Quantity : 10 Pieces

Material : Other, Biocompatible Medical Grade Material with Fabric Covering

Type : Other, Mitral Valve Repair Device

Size : Assorted (Specifically Sized per Patient)

Features : Enhanced Annular Remodeling, Biocompatible, Suture Markings

Application : Other, Mitral Valve Annuloplasty

Miral T Rigid Tricuspid Annuloplasty Ring

Miral T Rigid Tricuspid Annuloplasty Ring

Minimum Order Quantity : 10 Pieces

Material : Other, Biocompatible medical grade

Type : Other, Rigid

Size : 26, 28, 30, 32, 34, 36 mm

Features : MRLT26, MRLT28, MRLT30, MRLT32, MRLT34, MRLT36

Application : Other, Cardiac surgery



Back to top