Miral T Rigid Tricuspid Annuloplasty Ring Specification

  • Disposable Or Reusable
  • Single Use
  • Instruments Type
  • Cardiac implant
  • Surface Finish
  • Smooth
  • Instrument
  • Annuloplasty ring
  • Type
  • Rigid
  • Material
  • Biocompatible medical grade
  • Condition
  • New
  • Portable
  • Yes
  • Rechargeable
  • No
  • Foldable
  • No
  • Sterilized
  • Yes
  • Waterproof
  • Yes
  • Use Type
  • Tricuspid valve repair
  • Usage
  • Surgical
  • Operating Type
  • Manual
  • Application
  • Cardiac surgery
  • Features
  • MRLT26, MRLT28, MRLT30, MRLT32, MRLT34, MRLT36
  • Size
  • 26, 28, 30, 32, 34, 36 mm
  • Profile
  • Low profile design
  • Shape
  • C-shaped configuration
  • Rigid reinforcement
  • Yes
  • Color code
  • Blue reference line
  • MRI Compatible
  • Yes
  • Radiopaque markers
  • Present
  • Open ended design
  • Yes
  • Latex Free
  • Yes
  • Suture markers
  • Integrated
  • Non-absorbable
  • Yes
  • Product code
  • MRLT series
 

Miral T Rigid Tricuspid Annuloplasty Ring Trade Information

  • Minimum Order Quantity
  • 10 Pieces
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 2-5 Days
  • Main Domestic Market
  • All India
 

About Miral T Rigid Tricuspid Annuloplasty Ring



The Miral T Rigid Tricuspid Annuloplasty Ring (MRLT series) stands out as a popular and affordable solution for tricuspid valve repair in cardiac surgery. Designed with a C-shaped configuration and integrated suture markers, it unlocks optimum positioning and durability, thanks to its biocompatible medical grade material and rigid reinforcement. The ring features a blue reference line for easy identification and radiopaque markers for precise placement. Notable for its noble, smooth surface and latex-free, MRI-compatible properties, this noteworthy device is available in a range of sizes and is single-use, sterilized, and waterproof-ideal for consistent, reliable surgical application.

Versatile Commercial Utility for Cardiac Procedures

The Miral T Rigid Tricuspid Annuloplasty Ring is expertly crafted for surgical application, particularly in tricuspid valve repair during cardiac surgery. Its smooth, low profile and biocompatible material make it suitable for diverse hospital settings and cardiovascular centers. Featuring an open-ended design and radiopaque markers, it allows for precise placement and optimum outcomes. This annuloplasty ring supports manual operating use by cardiac surgeons, ensuring dependable results in medical procedures.


Market Availability & Delivery Logistics

Serving the main domestic market of India, the Miral T Rigid Tricuspid Annuloplasty Ring is accessible to reputable exporters, suppliers, and traders. Timely transportation is a priority, with a clear delivery time and reasonable outlay. Sample availability lets healthcare professionals examine quality before final outlay commitments. Charges associated with shipping and handling are communicated upfront, ensuring transparency at every stage of order fulfillment.


FAQ's of Miral T Rigid Tricuspid Annuloplasty Ring:


Q: How is the Miral T Rigid Tricuspid Annuloplasty Ring primarily used in cardiac surgery?

A: This ring is utilized for tricuspid valve repairs, providing rigid reinforcement during the annuloplasty procedure to aid in optimal and stable surgical outcomes.

Q: What benefits does the integrated suture and radiopaque markers provide?

A: Integrated suture markers facilitate accurate placement, while radiopaque markers assist surgeons in visualizing the ring's position during and after surgery, enhancing precision and safety.

Q: When can healthcare professionals request samples of the Miral T Ring?

A: Samples are available upon request prior to bulk purchase, allowing professionals to assess product quality and suitability without immediate full outlay.

Q: Where is the Miral T Annuloplasty Ring typically applied?

A: It is applied directly to the tricuspid valve during cardiac surgeries in hospitals and specialized cardiovascular treatment centers.

Q: What is the process for ordering and delivery within India?

A: Orders can be placed with authorized distributors or suppliers. Once confirmed, transportation and delivery occur within set timelines, with all charges outlined during the ordering process.

Q: How does the blue reference line assist during surgery?

A: The blue color code reference line enhances visibility during implantation, allowing surgeons to position the ring accurately for optimum performance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cardiovascular Instrument Category

Miral Annuloplasty Ring

Miral Annuloplasty Ring

Minimum Order Quantity : 10 Pieces

Sterilized : Other, Yes (sterile packed)

Dimension (L*W*H) : Varies by ring size (typically sizespecific)

Material : Other, Biocompatible medical grade material (commonly titanium core with polyester fabric covering)

Weight : Lightweight, implantable

Application : Other, Ring for mitral valve support

Miral Annuloplasty Ring

Miral Annuloplasty Ring

Minimum Order Quantity : 10 Pieces

Sterilized : Yes

Dimension (L*W*H) : Available in Multiple Standard Sizes

Material : Other, Biocompatible Medical Grade Material with Fabric Covering

Weight : Lightweight (Less than 50g)

Application : Other, Mitral Valve Annuloplasty

Sewing Ring

Sewing Ring

Minimum Order Quantity : 10 Pieces

Sterilized : Yes

Dimension (L*W*H) : Custom (varies by application)

Material : Other, Medical Grade Fabric and Synthetic Polymer

Weight : Lightweight

Application : Other, Heart Valve Annuloplasty Procedures

Nautica Intracoronary Shunt

Nautica Intracoronary Shunt

Minimum Order Quantity : 10 Pieces

Sterilized : Other, Yes, Sterile

Dimension (L*W*H) : Varies with sizes (standard micro sizes available)

Material : Other, Medicalgrade Silicone or Polymer

Weight : Ultralightweight

Application : Other, Temporary blood flow shunting during coronary artery bypass grafting



Back to top